Neumann’s Automatic Monitor Alignment MA 1 ensures the best possible sound quality in any room – from home studios to professional control rooms. Using the individually calibrated measurement microphone your acoustic environment is analyzed in a guided process. Advanced algorithms, derived from decades of experience in aligning reference monitoring systems, guarantee optimally aligned frequency response, time of arrival and level for exact and reliable monitoring.
A unique benefit of the MA 1 Algorithm is precise and effective compensation of room modes. Using MA 1 results in increased clarity, consistency across monitors, dry bass, and time-correct, more accurate depiction of reverbs and acoustic spaces.
Features:
- 4" Woofer
- 1" Tweeter
- Bi-Amped: LF 120W, HF 70W
- MMD Waveguide
- DSP Engine
- Standard IP Network Input
- Bass Extension: 57 Hz (-3 dB)
- Neumann.Control App
- Mac, Windows, iOS, Android Compatible
Specifications:
- Acoustical operating principle: Pressure transducer
- Directional Pattern: Omnidirectional
- Frequency Range: 20 Hz - 20 kHz
- Sensitivity at 1 kHz into 1 kohm: 30 mV/Pa -30 dBV +/- 3 dB uncalibrated | 30 mV/Pa -30 dBV +/- 0,5 dB Calibrated (via software)
- Rated Impedance: 50 Ohms
- Rated load impedance: 1000 Ohms
- Equivalent noise level, CCIR: 39 dB
- Equivalent noise level, A-weighted: 27 dB-A
- Maximum SPL for THD 0.5%: 132 dB
- Signal-to-noise ratio, CCIR (re. 94 dB SPL): 55 dB
- Signal-to-noise ratio, A-weighted (re. 94 dB SPL): 67 dB
- Maximum output voltage: 10 dBu
- Supply voltage (P48, IEC 61938): 48 V ± 4 V
- Current consumption (P48, IEC 61938): 3 mA
- Matching connector: XLR3F
- Weight: 37 g
- Diameter: 23 mm
- Length: 117 mm
- Operating conditions: 0 °C - +70 °C (32 °F - 158 °F); max. 90 % at +20 °C
- Transport/storage conditions: −20 °C - +70 °C (−4 °F - 158 °F); max. 90 % at +20 °C
- Acoustical operating principle: Pressure transducer
- Directional Pattern: Omnidirectional
- Frequency Range: 20 Hz - 20 kHz
- Sensitivity at 1 kHz into 1 kohm: 30 mV/Pa -30 dBV +/- 3 dB uncalibrated | 30 mV/Pa -30 dBV +/- 0,5 dB Calibrated (via software)
- Rated Impedance: 50 Ohms
- Rated load impedance: 1000 Ohms
- Equivalent noise level, CCIR: 39 dB
- Equivalent noise level, A-weighted: 27 dB-A
- Maximum SPL for THD 0.5%: 132 dB
- Signal-to-noise ratio, CCIR (re. 94 dB SPL): 55 dB
- Signal-to-noise ratio, A-weighted (re. 94 dB SPL): 67 dB
- Maximum output voltage: 10 dBu
- Supply voltage (P48, IEC 61938): 48 V ± 4 V
- Current consumption (P48, IEC 61938): 3 mA
- Matching connector: XLR3F
- Weight: 37 g
- Diameter: 23 mm
- Length: 117 mm
- Operating conditions: 0 °C - +70 °C (32 °F - 158 °F); max. 90 % at +20 °C