Martin Exterior AC-Feeder
Martin Exterior AC-Feeder
SKU: MAR-90580003
Available options

Description
Martin Exterior AC-Feeder
The Martin Exterior AC-Feeder is a smart, multi-protocol driver box for the Exterior Dot-1/4/9 Pro series. A compact design and IP66 rating make it perfectly suited for direct line voltage installations of Exterior Dot-1/4/9 Pro strings. The Exterior AC-Feeder provides the string with clean, regulated power and allows for a simple system layout with minimal-required system components.
Unifying unparalleled performance, adaptability, and intuitive operation, the Exterior Dot Pro family doesn’t just enable lighting designers and professionals to surpass the limitations of traditional systems, it inspires them to redefine the boundaries of creative video design.
Features
- Fully-weatherized housing (IP66, IK08 and C-5 High corrosion rating)
- Martin P3/Art-Net/sACN compatible (automatic protocol detection)
- Fail-safe bypass of Ethernet signal
- Setup and Addressing via RDM over Art-Net or Martin P3
- Real-time status feedback via RDM over Art-Net and Martin P3
- Local status LED and pushbutton to call up test patterns
- Thermal protection with automatic power reduction
- 100 - 240/277 VAC operation
- Internal terminal blocks for Power and Ethernet
- Hot-pluggable output connector (to Exterior Dot Pro strings)
- Surface- and truss-mountable
- Shipped in FSC-certified carboard packaging
- 5-year warranty
Specifications
Physical
- Length: 325mm (12.8in.) including flange bracket
- Width: 144 mm (5.6in.)
- Height: 69 mm (2.7 in.)
- Weight: 2.7 kg (5.95 lbs.)
Control and Programming
- Control Protocols: Martin P3, Art-Net or sACN
- Protocol detection: Automatic
- Setting and addressing: Martin P3 System controller or RDM (over Art-Net)-compliant controller
- RDM compliance: ANSI/ESTA E1.20
- Art-Net Compliance: Art-Net 1, 2, 3 and 4; including RDM over Art-Net
- sACN Compliance: ANSI E1.31 - 2016
- Martin P3 Compliance: P3 System Controller Software 6.1.0 or newer
- Ethernet Transceiver: 10/100Mbit (with fail-safe bypass)
- Firmware update: Via Ethernet using Martin Companion / P3 System Controller
Control/User Interface
- Device status: Multicolor status LED
- Device test and reset: Push button to call up local test patterns and reset device
Construction
- Housing: Aluminum
- Color: Black
- Surface treatment: Anodized and electrostatic powder-coated
- Protection rating: IP66
- Effective Projected Area (EPA): 0.062 m²
- Impact resistance: IK08
- Corrosion resistance: C5 High (ISO 12944-6)
- Vibration resistance: 1.0g, Sinusoidal (IEC 60068-2-6), 0,7g RMS Random (IEC 60068-2-64), 3.0g (ANSI C136-31)
Installation
- Orientation: Any
- Surface mounting: Four M6 mounting slots
- Truss mounting: M12 mounting hole for standard rigging clamp
Connections
- Output: Output cable tail with connector for Exterior Dot Pro string (Hot-pluggable)
- Power input or power & data input: M20 cable gland
- Power thru or power & data thru: M20 cable gland
- Ethernet cable input: M12 cable gland
- Ethernet cable thru: M12 cable gland
- Connection: Internal terminal blocks for Power and Ethernet
Electrical
- Output voltage: 15 VDC
- AC power: 100 - 240 / 277 V nominal, 50/60 Hz
- Power supply unit: Auto-ranging electronic switch-mode
- Typical half-cycle RMS inrush current: 2.5 A
- Surge protection: 4KV
- Maximum current draw: 1.1 A @100 V, 0.9 A @120 V, 0.5 A @230 V, 0.44 A @ 277 V
- Max earth leakage: 0.5 mA
- Power factor: 0.99 @110 V / 120 V, 0.92 @208 V / 230V, 0.90 @277 V
Power Consumption
- Maximum Power Consumption: 115 W at full load
- Idle: 6 W
- Hibernation: 2.5 W
* Measurements made at nominal voltage. Allow for a deviation of +/- 10%.
Idle: all LEDs at zero intensity. Maximum at full intensity, full white. Idle at zero intensity.
Hibernation: zero intensity, wake-up procedure to re-use fixture.
Thermal
- Cooling: Convection
- Maximum ambient temperature (Ta max.): 55° C (131° F)*
- Minimum ambient temperature (Ta min.): -30° C (-22° F)
- Total heat dissipation (calculated, +/- 10%): 51 BTU/hr at full load
*Above this temperature, the AC-Feeder regulates output to protect from overheating.
Environmental
- RoHS: Compliant
- REACH: Compliant
- WEEE: Compliant
- Proposition 65: Compliant
- FSC: Certified cardboard inlay and outer box
Approvals
- EU safety: EN 62368-1
- EU EMC: EN55032, EN55035, EN61000-3-2, EN61000-3-3
- US safety: UL 62368-1
- US EMC: FCC 47 CRF § 15 Class A
- Canadian safety: CSA C22.2 No. 62368-1
- Canadian EMC: ICES-003 Class A
- Australia/NZ: RCM
Related Items
- Martin P3-175 System Controller: P/N MAR-90721100
- Martin P3-275 System Controller: P/N MAR-90721101
- Martin P3-PC System Controller: Free download from martin.com
- Martin Companion Software: Free download from martin.com
- Exterior Dot-1 Pro, 115mm, 100pcs, 2m lead-in: P/N MAR-90580000
- Exterior Dot-4 Pro, 200mm, 64 pcs, 2m lead: P/N MAR-90580001
- Exterior Dot-9 Pro, 400mm 36pcs 2m lead: P/N MAR-90580002
Accessories
- Hybrid PDE-PDE Cables-1m (3.2 ft.): P/N 91616001
- Hybrid PDE-PDE Cables-2.5m (8.2 ft.): P/N 91616002
- Hybrid PDE-PDE Cables-5m (16.4 ft.): P/N 91616003
- Hybrid PDE-PDE Cables-10m (32.8 ft.): P/N 91616004
- Hybrid PDE-PDE Cables-25m (82 ft.): P/N 91616005
- PDE Cable Power-DMX-Ethernet Rental 100m (328 ft.): P/N 91616006
- Bulk Hybrid PDE Connectors-Male: P/N 91611701
- Bulk Hybrid PDE Connectors-Female: P/N 91611702
- PDE Cable tail Set: P/N MAR-90580025
Ordering Information
- Exterior AC-Feeder: P/N MAR-90580003