Martin Rush Club Smoke Pump Base Unit
The Rush Club Smoke Dual Pump Base Unit conceals a 10 l fluid reservoir, ensuring a continuous supply of fluid throughout busy nights to be located in a convenient location whilst the effect heads can be placed discreetly overhead in any orientation and remotely fed effect fluid.
Specifications:
Physical
- Pump unit
- Length: 415 mm (16.4 in.)
- Depth: 257 mm (10.2 in.)
- Height: 431 mm (17 in.)
- Weight, dry: 13.4 kg (29.5 lbs.)
- Weight. filled: 23.4 kg (51.5 lbs.)
Performance
- Coverage volume per fog head: 550 m3 (19, 423 ft 3) per minute
- Coverage volume per haze head: 2000 m 3 (70,629 ft 3) per minute
- Continuous effect output
- Fluid usage: Application specific
- Ready time: 7-minutes
Control and Programming
- Control options: Digital control panel, DMX, optional digital remote control, master/slave link mode
- Control options: Continuous or timer-controlled output
- Control zones: 3 zones; 2 matching heads per each zone
- Zone control: Independently controlled, automatic head detection
- Fog heads: Variable output per zone, 0-100%
- Haze heads: Variable output per zone; haze/fan proportionally controlled, 0-100%
- DMX channels: 4 Channels (Zone 1, Zone 2, Zone 3, Control)
- DMX compliance: ANSI E1.11 - USITT DMX512-A
Construction
- Pump unit
- Housing: Steel & aluminum
- Color: Black
- Fluid pump: 3 Oscillating piston, high pressure
- Fluid system: 10 l concealed and removable reservoir, optional external fluid connection kit (top and bottom inlet)
- Fluid management: Fluid out sensing
Installation
- Pump unit
- Mounting: Standing or wall-mountable
- Orientation: Horizontal only
- Maintain 150 mm (5.9 in.) clearance around and 300 mm (11.8 in.) above
Connections
- Pump unit
- AC power: IEC Male inlet, C14
- DMX in/out: 3- and 5-pin locking XLR
- Remote control: 3-pin locking XLR
- Data link to heads: 3x RJ45
- Fluid outlet: 3x push-to-connect tubing outlet, valved, 6 mm
- Firmware: AVR socket
Electrical
EU Model
- Pump unit
- AC power: 220-240 V, 50/60 Hz, 180 W
- Main fuse: 10 AT (slow-blow), 250 V
- Typical power and current: 180 W, 0.9 A*
US models
- Pump unit
- AC power: 100-130 V, 50/60 Hz, 180 W
- Main fuse: 3.15 AT, (slow-blow), 125 V
- Typical power and current: 180 W, 1.7 A*
*Measurements made at nominal voltage. Allow for a deviation of +/- 10%
Physical
Performance
Control and Programming
Construction
Installation
Connections
Electrical
EU Model
US models
*Measurements made at nominal voltage. Allow for a deviation of +/- 10%