Harris VTM-OPT Dual Composite Analog Input Module
Harris' Videotek® VTM Series™ features the world's first user configurable, field upgradeable, multi-format test and measurement console. The innovative modular platform makes the VTM Series fully customizable and affords broadcasters unprecedented flexibility to choose exactly how they'll apply Harris' Videotek® award-winning technology. The perfect solution for today's multi-format environment.
Features:
- User Configurable Hardware
- Display engine flexibility
- Dual auto detecting inputs for HD/SD-SDI, SD-SDI, or Analog Composite
- Standards: SMPTE-292M, SMPTE-259M-C, NTSC/PAL
- Multiple Reference Inputs
- Capability of displaying up to four different inputs simultaneously
- Customizable display functions, screen location, multiple displays
- Video Relative Timing display
- Patented Gamut display
- Pixel locator/Data Word Analyzer
- Picture Thumbnail
- A/B Parade and Overlay
- 608, 708 Closed Caption detect, alarm, display
- Teletext detect, alarm, display
- Comprehensive Alarm set, Peak Level Report
- 16 direct-access user presets
- Illuminated controls and indicators
- DVI-I output
- USB ports front and back for data transfer and mouse operation
- By-pass function enable
- 10/100BaseT Ethernet, SNMP agent, Web Server, SpyderWeb II
- GPI and Router control
Specifications:
- DISPLAY
- General: A quadrant display for viewing an input on up to four different displays as picture, waveform, vector, audio, alarm status, timing, optional eye pattern, simultaneously or individually as a full screen display of each separately. Additional data analyzer display for pixel analysis. Also view multiple waveform and vectors of the same or different inputs.
- Waveform: Composite, YCBCR or RGB, parade/overlay of like formats
- Sweep Time Base: 1H or 2H, with x1, x5 and x10 horizontal magnification 1V or 2V with x1, x5 and x25 horizontal magnification
- Waveform Accuracy: ≤ 1%
- Waveform Frequency Response
- Analog: 25 Hz to 5.75 MHz within ± 1% of amplitude at 50 kHz
- SD:
- ± 0.5% to 5.75 MHz Y
- ± 0.5% to 2.50 MHz CB, CR
- HD:
- ± 0.5% to 30 MHz Y
- ± 0.5% to 15 MHz CB, CR
- Sweep Time Base: Overlay (3 Eye) or 10 Eye (SD), 20 Eye (HD)
- Filters: 10 Hz, 100 Hz, 1 kHz
- Display Accuracy: ± 1%
- Measurement Analog Bandwidth: 250 kHz to 2250 MHz, -3 to +1 dB relative to 750 MHz
- Jitter Overshoot: ≤ 20% for all frequencies up to 300 kHz
- Intrinsic Jitter:
- < 70 ps for HD
- < 150 ps for SD
- Intrinsic Wander:
- < 150 ps for HD
- < 300 ps for SD
- Jitter: Bar graph showing jitter magnitude
- Display Range: 0 UI to 1.0 UI
- Vector:
- R - Y vs. B - Y for Analog
- CB vs. CR for HD or SD
- Vector Accuracy: ≤ 1°
- Gamut: Encoded or RGB Gamut displays with upper and lower limit selection
- Audio (Optional): 2, 4, 6 or 8 channels displayed simultaneously
- POWER REQUIREMENTS
- Power Input: 90 to 260 VAC, 50/60 Hz
- Power Consumption: 180 VA
- Dimensions:
- Height: 1.75" (4.5 cm)
- Width: 19.0" (48.3 cm)
- Depth: 19.75" (50.2 cm)
- ENVIRONMENTAL
- Operating Temperature: 0° to 50°C
- Storage Temperature: -40° to 65°C
- Humidity: 85% maximum (non-condensing)
- Operating Altitude: To 10,000 feet (3,050 m) above sea level
- DISPLAY
- General: A quadrant display for viewing an input on up to four different displays as picture, waveform, vector, audio, alarm status, timing, optional eye pattern, simultaneously or individually as a full screen display of each separately. Additional data analyzer display for pixel analysis. Also view multiple waveform and vectors of the same or different inputs.
- Waveform: Composite, YCBCR or RGB, parade/overlay of like formats
- Sweep Time Base: 1H or 2H, with x1, x5 and x10 horizontal magnification 1V or 2V with x1, x5 and x25 horizontal magnification
- Waveform Accuracy: ≤ 1%
- Waveform Frequency Response
- Analog: 25 Hz to 5.75 MHz within ± 1% of amplitude at 50 kHz
- SD:
- ± 0.5% to 5.75 MHz Y
- ± 0.5% to 2.50 MHz CB, CR
- HD:
- ± 0.5% to 30 MHz Y
- ± 0.5% to 15 MHz CB, CR
- Sweep Time Base: Overlay (3 Eye) or 10 Eye (SD), 20 Eye (HD)
- Filters: 10 Hz, 100 Hz, 1 kHz
- Display Accuracy: ± 1%
- Measurement Analog Bandwidth: 250 kHz to 2250 MHz, -3 to +1 dB relative to 750 MHz
- Jitter Overshoot: ≤ 20% for all frequencies up to 300 kHz
- Intrinsic Jitter:
- < 70 ps for HD
- < 150 ps for SD
- Intrinsic Wander:
- < 150 ps for HD
- < 300 ps for SD
- Jitter: Bar graph showing jitter magnitude
- Display Range: 0 UI to 1.0 UI
- Vector:
- R - Y vs. B - Y for Analog
- CB vs. CR for HD or SD
- Vector Accuracy: ≤ 1°
- Gamut: Encoded or RGB Gamut displays with upper and lower limit selection
- Audio (Optional): 2, 4, 6 or 8 channels displayed simultaneously
- POWER REQUIREMENTS
- Power Input: 90 to 260 VAC, 50/60 Hz
- Power Consumption: 180 VA
- Dimensions:
- Height: 1.75" (4.5 cm)
- Width: 19.0" (48.3 cm)
- Depth: 19.75" (50.2 cm)
- ENVIRONMENTAL
- Operating Temperature: 0° to 50°C
- Storage Temperature: -40° to 65°C
- Humidity: 85% maximum (non-condensing)
- Operating Altitude: To 10,000 feet (3,050 m) above sea level